  specification model dc voltage rated current current range rated power output voltage adj. range line regulation load regulation setup, rise time hold up time (typ.) voltage range note.5 frequency range efficiency (typ.) input inrush current (typ.) leakage current over temperature working temp. alarm signal output remote on/off control auxiliary power(aux) working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing overload over voltage ac current (typ.) 1500ms, 100ms at full load 10ms at full load 90 ~ 264vac 127 ~ 370vdc 47 ~ 63hz 17a/115vac 8a/230vac 30a/115vac 60a/230vac <2.0ma / 240vac 105 ~135% rated output power protection type : constant current limiting, recovers automatically after fault condition is removed 13.8 ~ 16.8v protection type : shut down o/p voltage, re-power on to recover 105 5 (tsw2 ) detect on heatsink of power transistor protection type : shut down o/p voltage, recovers automatically after t emperature goes down -20 ~ +70 (refer to output load derating curve) please see the function manual please see the function manual 12v@0.1a(only for remote on/off control) 20~90% rh non-condensing -40 ~ +85 , 10 ~ 95% rh 0.05%/ (0 ~ 50 ) 10 ~ 500hz, 2g 10min./1cycle, 60min. each along x, y, z axes 109k hrs min. mil-hdbk-217f (25 ) 278*127*83.5mm (l*w*h) 3.0kg; 4pcs/13kg/1.19cuft 86.5% 0.5% 0.5% 1.0% 14ms at full load 90% 30 ~ 34.8v 16ms at full load 90% 57.6 ~ 67.2v 150mvp-p 150mvp-p 200mvp-p 5% typical adjustment by vr, 20% ~ 110% (typ.) adjustment by 1~6vdc externa l control signal 12v 24v 48v 125a 63a 32a 0 ~ 125a 0 ~ 63a 0 ~ 32a 1500w 1512w 1536w SPV-1500-12 SPV-1500-24 SPV-1500-48 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. the power supply is considered a component which will be installed into a fi nal equipment. the final equipment must be re-confirmed that it still me ets emc directives. 5. derating may be needed under low input voltages. please check the derati ng curve for more details. for guidance on how to perform these emc tests, please refer to ?emi testing of c omponent power supplies.? (as available on http://www.meanwell.com) file name:SPV-1500-spec 2010-10-18 power factor (typ.) 0.95/230vac 0.98/115vac at full load safety standards harmonic current ems immunity ul60950-1, tuv en60950-1 approved compliance to en55022 (cispr22) compliance to en61000-3-2,-3 compliance to en61000-4-2,3,4,5,6,8,11; env50204, en55024, l ight industry level, criteria a ripple & noise (max.) note.2 voltage tolerance note.3 emi conduction & radiation withstand voltage isolation resistance i/p-o/p:3kvac i/p-fg:1.5kvac o/p-fg:0.5kvac i/p-o/p, i/p-fg, o/p-fg:100m ohms / 500vdc / 25 / 70% rh environment safety & function emc (note 4) protection universal ac input/full rangezvs new technology ac input active surge current limiting built-in active pfc function,pf>0.95 protections: short circuit / overload / over voltage / over temperature forced air cooling by built-in dc ball bearing fan high power density 8.3w/inch output voltage can be trimmed between 20% ~ 110% rated value current sharing up to 4500w(2+1) alarm signal output built-in 12v/0.1a auxiliary output for remote control built-in remote on-off control built-in remote sense function 3 years warranty 3 features : 1500w single output power supply s p v- 1 5 0 0 s e r i e s output voltage trim 4.8 ~ 28v 9.6 ~ 56v 2.4 ~ 13.2v
mechanical specification case no.943a unit:mm ac input terminal pin no. assignment pin no. 13 2 assignment ac/n ac/l pin no. pin no. 3 6 2 5 p ok gnd: power ok ground p ok: power ok signal rcg: remote on/off ground auxg: auxiliary ground rc1: remote on/off aux: auxiliary output 1 4 assignment assignment rcg p ok p ok gnd fg direction 93 air flow 16 i/p 3 2 -v 1 +v 17.5 10 13 240 11.2 16 max. 278 8-m4 l=5(both sides) 83.5 38 38.1 22.7 4-m4 l=5 127 11.2 240 led svr output 7 7 5 5 5 3 3 3 1 1 1 2 2 4 4 2 6 6 4 8 8 6 4 mating housing terminal or equivalent or equivalent block diagram pfc fosc : 70khz pwm fosc : 100khz fan o.v.p. -v +v rectifiers & filter -s +s circuit detection power aux remote control rc filter & rectifiers aux power (12v/0.1a) sharing load ls p ok limiting active current inrush control i/p switching power rectifiers filter emi pwm & pfc pfc control o.t.p. o.l.p. pin no. pin no. 2 14 3 rcg: remote on/off ground rc2: -s: -remote sensing remote on/off ls: load share pv: output voltage external control +s: +remote sensing ps: reference voltage terminal, ps and pv are connected when shipping assignment assignment rc2 rcg ps pv mating housing terminal or equivalent or equivalent 8 6 5,7 +s -s ls(current share) control pin no. assignment(cn3) : hrs df11-6dp-2ds or equivalent hrs df11-6ds hrs df11-**sc control pin no. assignment(cn1,cn2) : hrs df11-8dp-2ds or equival ent hrs df11-8ds hrs df11-**sc aux rc1 auxg cn1 cn2 cn3 1500w single output power supply s p v- 1 5 0 0 s e r i e s file name:SPV-1500-spec 2010-10-18
function manual 1.remote on/off (1)remote on/off control becomes available by applying voltage in cn1 & c n2 & cn3 (2)table 1.1 shows the specification of remote on/off function (3)fig.1.2 shows the example to connect remote on/off control functio n table 1.1 specification of remote on/off fig.1.2 examples of connecting remote on/off connection method sw logic output on sw open sw open sw open fig. 1.2(a) fig. 1.2(b) fig. 1.2(c) output off sw close sw close sw close 2.2k aux rc1 12v typ. auxg 150 rcg rc2 sw 620 5v 150 rc2 12v typ. rcg auxg 2.2k rc1 aux (a)using external voltage source (b)using internal 12v auxiliary output sw 150 rc2 12v typ. auxg sw rcg (c)using internal 12v auxiliary output 2.2k rc1 aux derating curve static characteristics ambient temperature ( ) load (%) 20 40 60 50 80 100 -20 0 10 20 30 40 45 50 60 70 input voltage (v) 60hz 100 90 80 70 60 load (%) ta=25 90 100 120 140 150 160 180 200 220 240 264 (horizontal) others 12v 1500w single output power supply file name:SPV-1500-spec 2010-10-18 s p v- 1 5 0 0 s e r i e s
file name:SPV-1500-spec 2010-10-18 3.external voltage control note: reference voltage terminal, ps and pv are connected when shipping 4.current sharing (1)parallel operation is available by connecting the units shown as bel ow (+s,-s and ls are connected mutually in parallel): (2)the voltage difference among each output should be minimized that le ss than 2% is required (3)the total output current must not exceed the value determined by the fol lowing equation (4) in parallel operation 3 units is the maximum, please consult the manufa cturer for other applications (5) when remote sensing is used in parallel operation, the sensing wire mus t be connected only to the master unit (output current at parallel operation)=(the rated current per unit) x ( number of unit) x 0.9 2.alarm signal output (1)alarm signal is sent out through "p ok" & "p ok gnd" pins (2)an external voltage source is required for this function. the maxim um applied voltage is 50v and the maximum sink current is 10ma (3)table 2.1 explains the alarm function built-in the power supply fig. 2.2 internal circuit of p ok (open collector method) external voltage and r (the max. sink is 10ma and 50v) p ok gnd p ok function p ok the signal is "low" when the power supply is 15% of the rated output voltage-power ok above low (0.5v max at 10ma) description output of alarm(p ok) the signal turns to be "high" when the power supply is under 15% of the rated output voltage-power fail high or open (external applied voltage 10ma max.) r v 0.1uf 100k +s load v- v+ -s ls ls -s +s cn1 cn2 no.1(master) ac/l ac/n no.2(slave) ac/l ac/n ls v- +s -s ls -s +s cn1 cn2 v+ ac/l ac/n ls v- +s -s ls -s +s cn1 cn2 v+ no.3(slave) +v -v +s -s table 2.1 explanation of alarm function 1 2 3 4 5 6 v vout 100 120 40 60 80 20 output voltage (%) external voltage (dc) non-linear ovp 120%(typ.) 40 60 80 100 120 v 100 40 60 80 20 output current (%) output voltage (%) 20 +s +v +v -v load -v -s pv 1~6v -s ps note : in parallel connection, maybe only one unit (master) operate if the to tal output load is less than 5% of rated load condition. the other psus (slaves) may go into standby mode and their output leds will not t urn on. 1500w single output power supply s p v- 1 5 0 0 s e r i e s


▲Up To Search▲   

 
Price & Availability of SPV-1500

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X